ABSTRACT

The heat parameters, the thermoanemometric flow-meter (TAF) errors and the experimental characteristics have been defined. The results of experiments were conducted with the help of physically-informational models allowing to realize all major thermal methods and their inherent informative options. The metrological evaluation was made and the sensitivity to the consumption of gas and liquid have been defined, their static and dynamic errors, followed by the comparison of costs according to these criteria. The developed method provides accurate measurement of volumetric flow of motor fuel 1.0-1.5% at heater temperature measurement accuracy of 1%.

KEYWORDS

Thermoanemometric flow-meter, biological fuel, physically-informational models